CARDIOLOGIA
- Eletrocardiógrafo Multicanal
AR 2100 ADV
Electrocardiografo Multicanal
Amulti-channel electrocardiograph offering performances
and flexibility on A4 format Automatic, manual and pre-programmed
recording mode Multi-channel print format on A4 paper: 3, 6x1, 6x2,
“Full Page” (3x4+R) and (3x4+3R), 12 channel LCD Display type for
ECG real time 3, 6, 6+6 channels Alphanumeric keyboard Dual power
supply: mains and rechargeable internal battery Memory of the last
ECG recording and printing of additional copies Time and date indication
Safe and easy wireless connection thanks to the IR (Infrared) digital
interface. Efficient and fast control of the recording quality thanks
to the multichannel graphic display able to visualize the ECG signal
before and during a recording with no need to print out immediately
on paper. User friendly interface the liquid crystal display, a
complete alphanumeric keyboard and dedicated keys for a quick access
to the main operating function, ensure quick and trouble free operation
of the ECG examination and patient management. Easily adapted to
suit your individual requirements the selection of the "options"
offered has no restrictions or constraints, it has no effect on
day-to-day use of the instrument and upgrades can be made directly
at your clinic or ward. In short, an A4 format electrocardiograph
providing solutions that will help improve the quality of diagnosis
performed by specialists and hospital staff alike
Options available:
Memory option: storage of more than 40 full ECG exams, with no need
to print out the ECG. ECG measurements option: automatic calculation
of the main ECG parameters. HES ECG analysis program: a useful and
dependable diagnostics support provided by the “HES” program. The
results obtained by analysing the 12 lead simultaneously, can be
printed out in a “physician tailored layout” following the methodology
with which a Physician would read an ECG. Arrhythmia program: detection
of arrhythmia events during continuous recording. HRV analysis option:
measurement of the heart rate variability in a predicted interval
(from 1 to 5 minutes) and printout of the relevant results. PC archive
option: archival storage of the ECG in a personal computer running
"L.E.M.S. - Local ECG Management System" software. The data upload
to the PC is made by use of the wireless “IR” interface; no direct
connection to the PC is required. PC ECG option: real time display
of the 12 ECG leads on a personal computer screen to allow management
of patient medical records and archiving of ECG’s in digital format
using "R.T.E. - Real Time ECG" software. “R.T.E” can offer an optional
HES module for automatic interpretation of the ECG signal.
Technical specifications
Power supply Internal AC power supply class I; 115-230 V ± 10% 50/60Hz
Rechargeable lead battery 12 Volt, 2000 mAh
Battery power capacity 1 hour
Writing system Thermal printer, 8 dot/mm. Usable print height 210
mm
Thermosensitive paper Format 210 mm in gridded Z-fold packets or
in rolls
Monitor Backlit graphic display 320x240 pixels (5,7 inches)
Keyboard Tactile keypad
Leads 12 standard leads
Signal memory 10 seconds each lead in automatic mode
Printout format Automatic mode: 3, 6x1, 6x2, Full Page(3x4+R)x1
and (3x4+3R)x1, 12x1
Manual mode: 3, 6, 12
Display channels 3, 6, 6+6
Operating modes Manual: acquisition and printing in real time
Automatic: simultaneous acquisition
Pre-programmed: in real time acquisition at programmable intervals
Arrhythmia: detection of arrhythmia events (optional)
HRV: acquisition and processing of heart rate variation (optional)
PC ECG: transmission of signal in real time to Personal Computer
(optional)
Recording/display sensitivity Manual: 5 10 20 mm/mV
± 5%
Automatic: according to number of channels printed
Paper transport speed 5 25 50 mm/s
Defibrillation protection Internal
Input dynamics ± 300 mV @ 0 Hz.± 10 mV band width
Input impedance > 100 MO on each electrode
Common mode rejection > 100 dB
Frequency response 0,05 ÷ 150 Hz
Time constant 3.3 s
Acquisition 12 bit
1000 samples/s/channel printing and filters
500 samples/s/channel in calculation and filters
Resolution 5 µV/bit
Pacemaker recognition Recognizes pulse in accordance with current
IEC standards
Filters Mains and muscle interference: modified digital notch 50
60 Hz
Anti-drift: digital high-pass 0.5 Hz, linear phase, without morphological
distortion
Serial interface Infrared
Diagnostics programs Parameter calculation (optional)
HES electrocardiogram interpreter
Arrhythmia program (optional)
HRV: heart rate variation (optional)
Options
- Memory option
- ECG measurements option
- ECG analysis option
- Arrhythmia option
- HRV analysis option
- PC archive option
- PC ECG option
Dimensions 325 x 80 x 345 mm (length x height x depth)
Weight 5000 grams without paper
Safety and Conformity Class I, type CF, CE0470. Ref: EN 60601-1,
to standards EN 60601-2-25, IEC 60601-2-51
|
|